Why is the electrostatic backpack sprayer more effective for disinfection?

 The most important thing for epidemic prevention and elimination is thorough disinfection. However, the disinfectant droplets sprayed by conventional disinfection equipment have large particles and poor adsorption, and the sprayed site is as wet as it has just been exposed to rain. In addition, in many cases, the corner gaps and the back of the object cannot be sprayed, making these blind areas a hidden danger.


The diameter of the mist droplets formed by the electrostatic backpack sprayer is only 40 microns, which is smaller than half of the diameter of the hair. Due to the electrostatic adsorption ability, when disinfecting one side of the object, the disinfectant droplets floating on the side and back of the object will also be affected by it. The electrostatic force produces an adsorption phenomenon, which achieves 360-degree enveloping disinfection with one spray side and multiple sides, and the disinfection is completed more thoroughly. The droplets carry static electricity to produce the adsorption, so that the disinfectant can be firmly attached to the target, and will not lose with gravity. The disinfectant left in the area sprayed once can be disinfected for a long time, saving the amount of medicine, and also greatly improving The effectiveness of disinfection.


Since the disinfectant droplets sprayed by the electrostatic backpack sprayer are small in diameter and charged with static electricity, they are not easy to fall and overcome gravity to suck back. It can accurately capture the suspended viruses in the air and block the hidden dangers of the spread of viruses floating in the air.


Common professional backpack sprayer failures and troubleshooting methods

  1. Insufficient spray pressure and poor atomization: If the water inlet ball valve is set up by dirt, you can remove the water inlet valve and clean the dirt with a cloth; if the cup is damaged, you can replace it with a new one; if it is due to the connection part If the sealing ring is not installed, or the air is leaking due to the damage of the sealing ring, the sealing ring can be installed or replaced.
  2. No fogging: If the oblique hole of the nozzle body is blocked by dirt, the oblique hole can be cleared; if the nozzle is blocked, the nozzle can be removed and cleaned. However, hard objects such as iron wire or copper needle can not be used to poke the nozzle to prevent The expansion of the holes makes the spray quality worse; if the filter in the casing is blocked or the water valve ball is set up, clean the filter and clean the dirt that has set up the ball.
  3. The switch leaks or cannot be screwed: if the switch cap is not tightened, the switch cap should be tightened; if the gasket on the switch core is worn out, the washer should be replaced; the switch cannot be screwed because it has been placed for a long time or used for a long time, The switch core is stuck due to the corrosion of the agent. The parts should be removed and cleaned in kerosene or diesel; if it is difficult to remove, it can be soaked in kerosene for a period of time, and then it can be removed after disassembly. Do not hit with hard objects.
  4. Water leakage in each connection part: if the joint is loose, the nut should be tightened; if the washer is not flat or damaged, the washer should be leveled or replaced; if the washer shrinks and hardens, it can be soaked in animal oil reuse.

 